4000A 11kv Indoor Three Phases Isolation Switch with Motor Operating Mechanism

Lieu d'origine Wenzhou
Nom de marque QIUPU
Certification IEC
Numéro de modèle GN22-12 / 4000A
Quantité de commande min 10pcs
Détails d'emballage WOODENS
Délai de livraison 7 jours
Conditions de paiement T / T, Western Union
Capacité d'approvisionnement 50000 PC / mois

Contactez-moi pour des aperçus gratuits et des bons.

whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

Si vous avez n'importe quel souci, nous fournissons l'aide en ligne de 24 heures.

x
Détails sur le produit
Tension de taux 11kV Tarifaire Pour les appareils électroniques
Courant stable chaud 12.5kA/4S Courant de Satble de mouvement 31.5kA/4S
Large 480 mm Courant court 40KA
Laisser un message
Description de produit

4000A 11kv Indoor Three Phases Isolation Switch with Motor Operating Mechanism

 

 

        1. We are specialty on epoxy resin medium voltage and high voltage components, such as 10KV, 24 KV and 40.5KV Circuit Breaker , Load breaker switch , Disconnecting Switch , Epoxy resin switchgear bushing , contactor box , insulators and transformer . 630A, 1250 A ,2500A , 3150A and 4000A contact box , club contact , fix contact, arm contact and jaw contact . 630A and 1250A VS1 circuit breaker . 630A and 1250A ZN85-40.5 circuit breaker . 12KV and 24KV earth switch. KYN28A-12 and KYN61 high voltage switchgear components!

 

        2. The Indoor high voltage isolation switch GN22-12(C) is use for three phase alternating current 50Hz , rate voltage is 12kV .

        3. Altitude is less than 1000 M .

 

        4. It is mainly used for "isolation power supply, turndown operation, for connecting and cutting off small current circuit", without arc extinguishing function.
The isolation switch, usually referred to as the high voltage isolation switch, is rated voltage above 1kV isolation switch, is the most used high voltage switch electrical appliances, working principle and structure is relatively simple, but because of the high usage, high reliability requirements, the design, construction and safe operation of power substation, power plant has a great impact.

 

 

Item Technical data
Rated voltage (KV)     12    
Rated frequency(Hz) 50
Insulator(capacity) insulating Frequency withstand voltage 5 min (KV)     42    
Frequency withstand voltage 1 min (V) 2000
Lighting impulse withstand voltage (KV)     75    
humitity 90%
light frequency voltage 85kV
   

 

        4000A 11kv Indoor Three Phases  Isolation Switch with Motor Operating Mechanism 04000A 11kv Indoor Three Phases  Isolation Switch with Motor Operating Mechanism 14000A 11kv Indoor Three Phases  Isolation Switch with Motor Operating Mechanism 2